• ÏêϸÐÅÏ¢

    IS6000Èý²ãÍòÕ×°²È«ÏµÁй¤Òµ¼¶19Ó¢´ç»ú¼Üʽ½»»»»ú£¬ÊÇ·ûºÏ¹¤ÒµÉè¼ÆÒªÇóµÄÈý²ãºËÐÄÍòÕ×»ú¼ÜʽÒÔÌ«Íø½»»»»ú£¬²ÉÓóÉÊìµÄ¼¼ÊõºÍ¿ª·ÅµÄÍøÂç±ê×¼£¬ÊÊÓ¦µÍθßΣ¬¿¹µç´Å¸ÉÈÅÇ¿£¬·ÀÑÎÎí£¬¿¹Õð·À¶¶£¬Å䱸ÈßÓàDC/AC¿ÉÑ¡µçÔ´£¬Âú×㹤ҵÏÖ³¡µÄÑÏ¿Á¹¤×÷»·¾³ÒªÇó£¬Îª¹¤ÒµÎïÁªÍøÌṩ¸ßЧ¡¢¿É¿¿¡¢¿ì½ÝµÄ½â¾ö·½°¸¡£
     

    IS6000Èý²ãϵÁй¤Òµ½»»»»ú¶¨Î»ÔÚÍøÂçºËÐÄ»ã¾Û²ã£¬¶Ë¿ÚÁé»îÅäÖã¬*¶àÖ§³Ö32¸ö¶Ë¿Ú£¬ÆäÖаüº¬4¸ö¹Ì¶¨ÍòÕ×SFP²å²Û£¨Ö§³Ö1G/10G¹âÄ£¿é£©£¬4¸ö¹Ì¶¨Ç§Õ×SFP²å²Û£¬ 8¸ö¹Ì¶¨Ç§Õ×µç¿ÚRJ45µç¿Ú£¬¿ÉÑ¡4¸ö¹¤³§¶¨ÖÆ»¯½Ó¿ÚÄ£¿é£¬4¸ö½Ó¿ÚÄ£¿é°´Ðè×éºÏ£¬½Ó¿ÚÄ£¿éµç¿Ú¡¢¹â¿Ú½Ó¿Ú¿ÉÑ¡¡£¸ù¾ÝÓû§ÐèÇ󹤳§»¯¶¨ÖÆ£¬¿É¹ã·ºÓ¦ÓÃÔÚ¹¤Òµ¿ØÖÆ×Ô¶¯»¯¡¢µÀ·½»Í¨¿ØÖÆ×Ô¶¯»¯¡¢¿ó¾®×Ô¶¯¿ØÖÆϵͳ¡¢ÓÍÌï¿ØÖÆ×Ô¶¯»¯¡¢Ë®µçÕ¾¿ØÖÆ×Ô¶¯»¯¡¢µçÁ¦ÏµÍ³¿ØÖÆ×Ô¶¯»¯£¬»ú·¿¼à¿ØϵͳµÈ¹¤ÒµÓ¦Óó¡¾°£¬Îȶ¨¿É¿¿¸ßЧ¹¤×÷£¬´òÔìÎÈÈçÅÍʯµÄ¹¤ÒµÎïÁªÍø¡£

     

    ¹Ø¼üÌØÐÔ

    *¶àÖ§³Ö32¸ö¶Ë¿Ú,¹Ì¶¨4ÍòÕ×SFP ²å²Û£¨1G/10G×ÔÊÊÓ¦£©+4¸öǧÕ×SFP²å²Û+8¸öǧÕ× RJ45µç¿Ú£¬16¸öGE¶Ë¿Ú£¨4×é°å¿¨ÊµÏÖ£©

    Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPFµÈÈý²ã·ÓÉЭÒé

    Ö§³ÖSTP/RSTP/MSTP£¬VRRPµÈÈßÓàЭÒé

    Ö§³ÖIGMP snooping¡¢DHCP Snooping

    Ö§³ÖITU G.8032 ±ê×¼µÄERPS »·ÍøЭÒ飬×ÔÓúʱ¼äСÓÚ20ms

    ¸ß¿É¿¿ÐԵĹ¤ÒµÍøÂ簲ȫϵͳ

    -40¡æ¡«+75¡æ¿íÎÂÉè¼Æ£¬È·±£É豸ÊÊÓ¦¸÷ÖÖÑÏ¿áµÄÏÖ³¡»·¾³

    IP40µÈ¼¶·À»¤£¬¸ßÇ¿¶È½ðÊôÍâ¿Ç£¬ÎÞ·çÉÈ£¬µÍ¹¦ºÄÉè¼Æ

    ²úÆ·¹æ¸ñ

    ½Ó¿ÚÐÅÏ¢

    ¹Ì¶¨½Ó¿Ú£º4¸öÍòÕ×SFP²å²Û(Ö§³Ö1G/10G¹âÄ£¿é)£¬4¸öǧÕ×SFP²å²Û£¬8¸öRJ45 µç¿Ú£¬10/100/1000Mbps ×ÔÊÊÓ¦ 

    Áé»î½Ó¿Ú£º¿ÉÅä4¸ö½Ó¿ÚÄ£¿é£¬Ã¿¸öÄ£¿éÖ§³Ö4¸öǧÕ×½Ó¿Ú£¬µç/¹â½Ó¿ÚÄ£¿é¿ÉÑ¡£¬*¶àʵÏÖ16¸öǧÕ׶˿Ú

    Console¿Ú£ºÌṩ1 ¸öRJ45 µ÷ÊÔ´®¿Ú

    »úе½á¹¹

    Íâ¹Û³ß´ç£º482 mm× 44 mm× 300 mm

    °²×°·½Ê½£º»ú¼Üʽ°²×°¡¢×ÀÃæʽ

    ÖØ    Á¿£º<4kg

    ·À»¤µÈ¼¶£ºIP40

    »·¾³ÒªÇó

    ¹¤×÷ζȣº-40¡æ¡« +75¡æ

    ´æ´¢Î¶ȣº-40¡æ¡« +85¡æ

    Ïà¶Ôʪ¶È£º5% ¡« 95%£¨·ÇÄý¶£©

    MTBF : ≥500000 Сʱ

    ½»»»ÊôÐÔ

    MACµØÖ·±í£º128K

    VLAN : 4K

    ת·¢·½Ê½£º´æ´¢×ª·¢

    ת·¢Ö¡³¤£ºÖ¡³¤¿É´ï10000Bytes

    ´«Êä¾àÀë

    Ë«½ÊÏߣº100m£¨±ê×¼CAT5/CAT5e ÏßÀ£©

    ¶àÄ£¹âÏË£º850nm £¬2Km£»1310nm £¬5Km

    µ¥Ä£¹âÏË£º1310nm£¬20Km£»1310nm£¬40Km£»

    1310nm £¬60Km£»1550nm £¬80Km

    µçÔ´ÒªÇó

    ¹¤×÷µçѹ£º90~260VAC»ò100~300VDC

    Õû»ú¹¦ºÄ£º≤45W

      Èí¼þÌØÐÔ

    ·ÓÉЭÒ飺IPv4¾²Ì¬Â·ÓÉ¡¢RIPv1v2¡¢OSPFÒÔ¼°SVI·ÓÉ£¨VLAN¼ä·ÓÉ£©,Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ

    Èý²ã×é²¥£ºÖ§³ÖÓòÄÚ×鲥·ÓÉЭÒéPIM-SM

    Èý²ãÈßÓࣺVRRP

    ÈßÓàÍøÂ磺֧³ÖSTP/RSTP/MSTP£¬Ö§³ÖERPS

    ×é²¥Ö§³Ö£ºÖ§³ÖIGMP Snooping V1/V2/V3£¬Ö§³ÖGMRP 

    VLAN£ºÖ§³ÖIEEE 802.1Q 4K VLAN

    Á´Â·¾ÛºÏ£ºÖ§³ÖÊÖ¹¤¾ÛºÏ£¬Ö§³Ö¾²Ì¬/ ¶¯Ì¬LACP ЭÒé

    QOS£ºÖ§³ÖCOS¡¢DSCP£¬8 ¸ö¶ÓÁУ¬Ö§³ÖWRR¡¢SP¡¢WFQµ÷¶Èģʽ£¬²ßÂÔQOS

    Õï¶Ïά»¤£ºÖ§³Ö¶Ë¿Ú¾µÏñ(1:1, 1:N, N:N) ,Ö§³ÖSyslog£¬Ö§³ÖPing ÃüÁîµÈ

    ¹ÜÀí¹¦ÄÜ£ºÖ§³ÖCLI¡¢WEB¡¢SNMP v1v2v3 ¹ÜÀí·½Ê½¼°ºñʯNIS¹ÜÀíϵͳ

    ¸æ¾¯¹ÜÀí£ºÖ§³Öһ·¼ÌµçÆ÷¸æ¾¯£¬Ö§³ÖRMON ¹ÜÀí£¬TRAP ¸æ¾¯

    °²È«¹¦ÄÜ£ºÖ§³ÖDHCP Snooping, Option 82£¬Ö§³Ö802.1X£¬Ö§³ÖÓû§·Ö¼¶¹ÜÀí£¬Ö§³ÖACL ·ÃÎÊ¿ØÖÆÁÐ±í£¬Ö§³ÖACL Logging¡¢ACL Counter¡¢ACL Remark¡¢ACLÖض¨Ïò£¬Ö§³ÖDDOS£¬Ö§³Ö»ùÓڶ˿ڵÄMAC£¬IPµØÖ·¹ýÂË/ °ó¶¨£¬Ö§³ÖSSL/SSH, Ö§³ÖARP·ÀÆÛÆ­¹¦ÄÜ¡£Ö§³ÖÕë¶Ô·Ç·¨±¨ÎĶÔCPUµÄ¹¥»÷µÄ±£»¤»úÖÆ

    ½ÚÄܹ¦ÄÜ£ºÖ§³ÖIEEE 802.3az½ÚÄܱê×¼,Ö§³Ö¶Ë¿ÚÐÝÃß

    Êý¾Ý¿ØÖÆ£ºÖ§³Ö»ùÓÚingress/egress µÄ¶Ë¿ÚÏÞËÙ£¬Ö§³Ö°ëË«¹¤±»Ñ¹Ê½Á÷¿ØÒÔ¼°802.3X È«Ë«¹¤Á÷¿Ø£¬Ö§³Ö»ùÓڹ㲥¡¢×é²¥¡¢Î´Öªµ¥²¥µÄ·ç±©ÒÖÖƹ¦ÄÜ

    ָʾµÆ  

    µçԴָʾµÆ£ºP1¡¢P2 

    ϵͳÔËÐÐָʾµÆ£ºSYS

    ¸æ¾¯×´Ì¬Ö¸Ê¾µÆ£ºALM

    ¶Ë¿Ú״ָ̬ʾµÆ£ºÇ§Õ׶˿ڣ¨G1¡«G28£©£¬ÍòÕ׹̶¨¹â¿Ú£º(X1¡«X4)

    ±£ÐÞÆÚ

    5Äê

    ·ûºÏµÄÏà¹ØÐÐÒµÈÏÖ¤±ê×¼

    IEC61000-4-2£¨ESD£©£º±8kV ½Ó´¥·Åµç£¬±15kV ¿ÕÆø·Åµç

    IEC61000-4-3£¨RS£©£º10V/m£¨80¡«1000MHz£©

    IEC61000-4-4£¨EFT£©£ºµçÔ´Ïߣº±4kV£»Êý¾ÝÏߣº±2kV

    IEC61000-4-5£¨Surge£©£ºµçÔ´ÏߣºCM±4kV/DM±2kV£»Êý¾ÝÏߣº±4kV

    IEC61000-4-6£¨ÉäƵ´«µ¼£©£º10V£¨150kHz¡«80MHz£©

    IEC61000-4-8£¨¹¤Æµ´Å³¡£©£º100A/m ³ÖÐø£»1000A/m £¬1s to 3s

    IEC61000-4-9£¨Âö³å´Å³¡£©£º1000A/m

    IEC61000-4-10£¨×èÄáÕñµ´£©£º100A/m

    IEC61000-4-12/18£¨Õðµ´²¨£©£ºCM 2.5kV£¬DM 1kV

    IEC61000-4-16£¨¹²Ä£´«µ¼£©£º30V ³ÖÐø£»300V,1s

    FCC Part 15/CISPR22£¨EN55022£©£ºClass A

    IEC61000-6-2£¨Í¨Óù¤Òµ±ê×¼£©

    IEC60068-2-6£¨¿¹Õñ¶¯£©

    IEC60068-2-27£¨¿¹³å»÷£©

    IEC60068-2-32£¨×ÔÓÉÏÂÂ䣩

    IEC61850-3£¨±äµçÕ¾£©

    IEEE1613£¨µçÁ¦·ÖÕ¾£©

    EN60950-1 (ÐÅÏ¢¼¼ÊõÉ豸°²È«£¬Å·ÃË)

    UL60950-1 (ÐÅÏ¢¼¼ÊõÉ豸°²È«£¬ÃÀ¹ú)

    ¹ìµÀ½»Í¨ÐÐÒµ±ê×¼£ºEN50155,EN50121-3-2,EN50121-4,IEC61373

     

    ¶©¹ºÐÅÏ¢

    ²úÆ·ÐͺÅ

    ¶Ë¿Ú

    ÍòÕ×¹â¿Ú

    ǧÕ×¹â¿Ú

    ǧÕ×µç¿Ú

    Áé»î¶Ë¿Ú

    IS6000-6532-4GF-4XGF-3A-2AD

    4x10G

    SFP²å²Û

    4x1G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    16xǧÕ׶˿Ú

    (4x½Ó¿Ú°å¿¨)

    IS6000-6532-4GF-4XGF-3A-AD

    4x10G

    SFP²å²Û

    4x1G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    16xǧÕ׶˿Ú

    (4x½Ó¿Ú°å¿¨)

    IS6000-6532-8GF-4XGF-3A-2AD

    4x10G

    SFP²å²Û

    8x1G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    12xǧÕ׶˿Ú

    (3x½Ó¿Ú°å¿¨)

    IS6000-6532-12GF-4XGF-3A-2AD

    4x10G

    SFP²å²Û

    12x1G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    8xǧÕ׶˿Ú

    (2x½Ó¿Ú°å¿¨)

    IS6000-6532-16GF-4XGF-3A-2AD

    4x10G

    SFP²å²Û

    16x10G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    4xǧÕ׶˿Ú

    (1x½Ó¿Ú°å¿¨)

    IS6000-6532-20GF-4XGF-3A-2AD

    4x10G

    SFP²å²Û

    20x10G

    SFP²å²Û

    8xǧÕ×

    RJ45µç¿Ú

    0xǧÕ׶˿Ú

    (0x½Ó¿Ú°å¿¨)

    ISM6500-4GE

    °å¿¨£¬4¸ö10/100/1000Base-T(X) RJ45½Ó¿Ú

    ISM6500-4GF

    °å¿¨£¬4¸ö100M/1GBase-FX SFP²å²Û£¨²»º¬Ä£¿é£©

  • ÁôÑÔ

    *ÏêϸÐèÇó£º
    *ÊÖ  »ú£º
    Áª ϵ ÈË£º
    µç    »°£º
    E-mail£º
    ¹«  ˾£º
    ¡¶¹ÈÆÙ·þÎñÌõ¿î¡·¡¶Òþ˽Õþ²ß¡·
  • ²úÆ·ËÑË÷

  • Áô ÑÔ

    ÀîÉú ÏÈÉú

    ¡¶¹ÈÆÙ·þÎñÌõ¿î¡·¡¶Òþ˽Õþ²ß¡·
ÉîÛÚÊкñʯÍøÂç¿Æ¼¼ÓÐÏÞ¹«Ë¾ µØÖ·£º ÉîÛÚÊÐÄÏɽÇøÎ÷Àö½ÖµÀ°×âÉçÇøɳºÓÎ÷·5298ºÅ°ÙÍúÑз¢´óÏÃ1¶°801
ÄÚÈÝÉùÃ÷£º¹ÈÆÙΪµÚÈý·½Æ½Ì¨¼°»¥ÁªÍøÐÅÏ¢·þÎñÌṩÕߣ¬¹ÈÆÙ£¨º¬ÍøÕ¾¡¢¿Í»§¶ËµÈ£©ËùչʾµÄÉÌÆ·/·þÎñµÄ±êÌâ¡¢¼Û¸ñ¡¢ÏêÇéµÈÐÅÏ¢ÄÚÈÝϵÓɵêÆ̾­ÓªÕß·¢²¼£¬ÆäÕæʵÐÔ¡¢×¼È·ÐԺͺϷ¨ÐÔ¾ùÓɵêÆ̾­ÓªÕ߸ºÔð¡£¹ÈÆÙÌáÐÑÄú¹ºÂòÉÌÆ·/·þÎñÇ°×¢Òâ½÷É÷ºËʵ£¬ÈçÄú¶ÔÉÌÆ·/·þÎñµÄ±êÌâ¡¢¼Û¸ñ¡¢ÏêÇéµÈÈκÎÐÅÏ¢ÓÐÈκÎÒÉÎʵģ¬ÇëÔÚ¹ºÂòǰͨ¹ý¹ÈÆÙÓëµêÆ̾­ÓªÕß¹µÍ¨È·ÈÏ£»¹ÈÆÙÉÏ´æÔÚº£Á¿µêÆÌ£¬ÈçÄú·¢ÏÖµêÆÌÄÚÓÐÈκÎÎ¥·¨/ÇÖȨÐÅÏ¢£¬ÇëÔÚ¹ÈÆÙÊ×Ò³µ×À¸Í¶ËßͨµÀ½øÐÐͶËß¡£